One mattress. Three layers of care.

LenexaCARE® is built on one bed: a pressure-redistributing foam mattress, fabric sensing in its fitted cover, and a pre-warning at the edge that runs on the same sensor.

Scroll to build the bed, one layer at a time

  1. 01

    A three-layer, pressure-redistributing foam mattress with firm side walls, for residents at risk of pressure injuries.

  2. 02

    Fabric sensors in the mattress cover show each person’s position and how long they have held it, against the protocol you set.

  3. 03

    The same sensor shows your team when a resident moves to the edge of the bed, before they get up.

Measured in Australian aged care.

A 35-week evaluation in two residential aged care homes: a six-week blinded baseline, then 29 weeks with LenexaCARE® enabled.1 The same 16 residents were measured before and after.

0 new pressure injuries in monitored residents over 29 weeks, against 4.8 expected.

Turn compliance +16.5 pts
Baseline
52.0%
Enabled
68.5%
High-risk time −17.4 pts
Baseline
40.5%
Enabled
23.1%
Read the results with their limits

What your team sees, and what sits on the bed.

A turn chart shows that a turn was recorded. It cannot show the position someone is in now, or how long they have been there. In a trial with ventilated intensive care patients, only 39% of turns were held for 15 minutes, the time set to relieve pressure.2

What you get: the LenexaCARE® static foam mattress with sensing in its fitted cover, a Databox on the bed, and the ward view.

Recorded demonstration. The pressure map and the position timeline follow the person on the mattress as they turn.
The LenexaCARE Databox: a small white hub with power, sensor and data connections
In the cover
Sensing sits on the underside of the cover, beneath normal linen.
On the bed
The Databox sends data to the ward view.
On the screen
Position and time, at the station or on a tablet.
Nothing to wear
No cameras, no wearables, nothing attached to the person.

Ready for your governance.

Regulatory status and data handling for LenexaCARE®, stated as certified.

Included in the ARTG
Class I · ARTG 475785
ISO 13485:2016
Certified quality management system
IEC 60601-1, -1-2
Safety and EMC tested
No resident identifiers
Encrypted, and kept in-country
HL7/FHIR or standalone
EMR integration is optional
Wipe-clean cover
Medical-grade disinfectants

Market presence

LenexaCARE® is approved for deployment in multiple international markets.

Start with one wing. Scale when you’re ready.

  • Typically installed and commissioned in 1–2 days
  • Clinical and IT training from our team
  • Purchase or subscription, with flexible terms

Talk to us about equipping your ward or home.

contactus@lenexamedical.com

Sources

  1. Yang W, Wood B, Lindsay J, Savaglio M. 2026. Manuscript in preparation. Methods and definitions on request.
  2. Pickham D, et al. Int J Nurs Stud. 2018;80:12–19.